2.3 Shelf Requirements

The drawing below show the framing requirements if you desire
the air discharge opening to be located within the bump-out or
bookshelf framing.
7"
(178mm)
MIN
3"
(76mm)
MIN
76"
(1930mm)
MIN
Enclosure Floor
Figure 2.7, CLW-50 Shelf Requirements
12 FRAMING AND CLEARANCES
2"
(51mm)
MIN
22"
(559mm)
MIN
18"
(457mm)
MIN
7"
(178mm) MIN
Grille
3"
(76mm)
MIN
18"
(457mm)
MIN
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
2.3.1 CLW-50 Requirements
NOTE: For the CLW-50, take careful consideration in the difference
of the minimum chamber height of the fireplace compared to the
minimum height of the shelf enclosure.
CLW-50
Enclosure Top
22"
(559mm)
MAX
76"
22"
(1930mm)
(559mm)
MIN
MIN
¾
82
"
(2102mm)
MIN
Ceiling
7"
(178mm)
MIN
Grille
¾
82
"
(2102mm)
MIN
Enclosure Floor
Komfort Zone Kit #KZK-1510A R.4