3.2 Combustible Finish

NOTE: If you desire to run finishing material up to edge of the discharge
opening, see drawing below. Finishing material must not block the air
discharge grille and must be run evenly along the plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
3.2.1 Drywall Finish
IMPORTANT: Additional 1" (25mm) combustible trim on top of
existing materials is NOT allowed inside the side shelf enclosure
(Section 2.3 Shelf Requirements on page 12.)
1" (25mm) combustible material goes on top of any required non-
combustible material required on the fireplace as shown in Figures
3.1 and 3.2 on page 10 for CLW-50 and Figure 3.3 on page 11 for
BHM-44.
1" combustible material goes on top of any required non-combustible material required on replace.
11
"
(301mm)
Figure 3.4, #KZK-1510A Drywall Finish and Combustible Finishing Material up to 1" Thick
16 FACING AND FINISHING
Drywall stops at edge of air discharge opening.
Air grille discharge will overlap edges of drywall.
¼
7
" (184mm)
Up to 1" (25mm) thick combustible material up to edge of the air discharge grille.
1" combustible material cannot go closer to discharge opening.
15
"
(403mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
½
15
"
(368mm)
Combustible
Material up to
1" (25mm) thick
Discharge Grille
NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE
11
"
(301mm)
Komfort Zone Kit #KZK-1510A R.4