Télécharger Imprimer la page

AKO-Agrartechnik Power Profi Ni 7000 Consignes D'utilisation page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
Specific Operating Instructions
1
2
3
4
a.) Installation
Fastening holes (4) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall
with the connections at the bottom, see above picture, left part. For outside installation the device must also
be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses
(green or red). The device is ready for operation. If control lights do not flash, the power supply or power
supply line must be checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (earthing + fence)
Flashing green:
Control light
fence
1
Flashing red:
(1)
Flashing green:
Control light
Flashing
2
earth (2)
red:
The unit can be operated with a SEPARATE fence system connected to each fence connection (6 – 7).
If both fence exits are used simultaneously, the control light (1) refers to exit (7) with maximum energy.
If the indicator light flashes faster than once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
After a delay time of 15 seconds this device is able to deliver output energy of over 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore
automatically adjusts the shock strength to the increased growth, weather conditions and fence status.
If the device is operating with a lower load (more than 1000 Ohm) and the load suddenly increases so
significantly that the load resistance drops below 400 Ohm for more than 6 pulses then the device goes into
an alarm mode.
The pulse interval is then extended to 3 seconds, the device issues an acoustic and visual alarm (all signal
lights flash rapidly in red).
If the load lasts more than 10 minutes then the alarm ends and the system switches back to the normal pulse
frequency.
If the load drops again within 10 minutes of switching on the alarm and the load resistance thereby exceeds
600 Ohm, the alarm is cancelled and the device resumes normal operation.
!!!Should the device be in the alarm mode, it must be switched off immediately and the fence arrangement be
checked!!!
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty terms and
conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
4
5
7
6
Mains plug is used as ON / OFF!
230 V ~!
Connection to
This energizer shall not be used as an animal trainer
(inside a barn).
State of fence ok = output voltage > 3500V = minimum requirement
State of fence faulty = output voltage ≤ 3500V, see operating instructions
enclosed, possible sources of error (fig. 2, pg.5)
State of connection to earth ok; earth voltage < 1000 V
State of connection to earth faulty, earth voltage ≥ 1000 V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5) and connection to
earth (pg.4)
1
2
3
4
5
6
7
3
Indicator light fence
Indicator light earth
230V-Consumption
announcement in %
(25% = green; 50 - 100% = red)
Fastening holes
Earth connection
Fence connection
with reduced energy
Fence connection
with maximum energy
-EN-
Version : 2016.2

Publicité

loading

Ce manuel est également adapté pour:

Power profi ni 10000