Wall And Ceiling Protection; Installation - Napoleon HDX52NT-2 Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour HDX52NT-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

16

4.0 INSTALLATION

EN
ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP
IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE, ENSURE THE REMOTE RECEIVER IS IN THE
"OFF" POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE.
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
ALL EXHAUST AND INTAKE VENT PIPE JOINTS MUST BE SEALED USING RED RTV HIGH TEMP
SILICONE SEALANT (W573-0002) (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC (W573-0007)
(NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, A MINIMUM OF 3 SCREWS MUST ALSO
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
4.1

WALL AND CEILING PROTECTION

DO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OF
MATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS.
ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS.
INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OR
For optimum performance it is recommended that all horizontal runs have a minimum of
per foot (0.3m) using fl exible venting. For safe and proper operation of the appliance, follow the venting
instructions exactly.
For clearance to combustible materials from the vent pipe, see "FRAMING" section.
W415-2180 / B / 08.29.18
THE GAS AND ELECTRICAL SUPPLY.
BE SEALED USING MILL PAC.
BE USED TO ENSURE THE CONNECTION CANNOT SLIP OFF.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
MAINTAIN CLEARANCES TO COMBUSTIBLES.
OTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.
WARNING
!
EXACTLY.
WARNING
!
68.2D
70.1
1/4"
(6.4mm) rise

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hdx52pt-2

Table des Matières