General Safety; Technical Specifications - BFT LUX Instructions D'utilisation Et D'installation

Automations a piston pour portails battants
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336 EEC and
73/23/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
• Keep the instructions together with the technical brochure for future reference.
• This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the following
European Directives: 89/336/EEC, 73/23/EEC and subsequent amend-
ments. As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in order to
achieve a good safety level.
• The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
• The installation must comply with the provisions set out by the fol-
lowing European Directives: 89/336/EEC, 73/23/EEC and subsequent
amendments.
• Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
• Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
• Only use original parts for any maintenance or repair operation.
MOD
TYPE OF LOCK
LUX
electric lock
LUX B
hydraulic closing
LUX 2B
hydraulic clos./open
LUX L
electric lock
LUX G
electric lock
LUX GV
electric lock
LUX MB
hydraulic closing
INSTALLATION MANUAL
• Do not modify the automation components, unless explicitly authorised
• Instruct the product user about the control systems provided and the
• Do not allow persons or children to remain in the automation operation area.
• Keep radio control or other control devices out of children's reach, in order
• The user must avoid any attempt to carry out work or repair on the automa-
• Anything which is not expressly provided for in the present instructions,
• Installation must be carried out using the safety devices and controls
2) GENERAL OUTLINE
A compact, sturdy oleodynamic piston, available in a wide range of models
to fit any need and field of operation. It is available in versions both with or
without (reversible) hydraulic lock, that need to be equipped with an electric
lock to hold the gate both closed and open.
The emergency release is obtained with the special key provided.
The adjustment of the pushing force is extremely precise and is performed by
means of two by-pass valves that act as an antisquash safety. The operation at
the end of the stroke is controlled electronically by a timer in the control panel.
The LUX series includes special versions with slowdown in the closing phase
(Mod. "R") while the LUX FC series is especially suited to areas prone to
heavy snowfalls or where the central gate stop cannot be provided (see
specific instruction manual).
3) THE MAIN PARTS IN THE AUTOMATION (fig. 1)
M)
P)
D)
C)
Standard components:

4) TECHNICAL SPECIFICATIONS

Power supply: ......................................................... 230V~±10% - 50 Hz (*)
Motor: ..........................................................................................2800 min
Power absorption: ............................................................................... 250W
Capacitor: .......................................................................................... 6.3 µF
Current absorption: ............................................................................... 1.4A
Max. pressure: ................................................................................... 30 bar
Pump delivery: ...........................................................................See Table 1
Pushing force: ....................................................................................3000N
Pulling force: .....................................................................................2600 N
Working stroke: ..........................................................................See Table 1
Impact reaction: ...................................................................hydraulic clutch
Manual manoeuvres: ............................................................ by release key
Max. no. manoeuvres in 24: ....................................................... See table 1
Thermal protection: ........................................................................... 160° C
Ambient temperature: .......................................................... -10° C ÷ 60° C
Protection:............................................................................................ IP 57
TABLE 1
PUMP
WORKING TIME
l/min
(s)
1.2
17
1.2
17
1.2
17
0.6
33
0.6
48
1.2
28
0.9
23
by the company.
manual opening operation in case of emergency.
to avoid unintentional automation activation.
tion system, and always request the assistance of qualified personnel.
is not allowed.
prescribed by the EN 12978 Standard.
Warning: during the first manoeuvring cycles, some oil may leak out
after being deposited in the breather channel during transport.
Warning: an excessively fast manual manoeuvre can cause oil to leak
out.
Single phase 2 pole motor protected by thermal circuit breaker
Hydraulic lobe pump
Fluid distributor with adjustment valves
Cylinder with piston
gate post and gate brackets - release key and bypass adjustment
drive capacitor - instruction booklet.
MAX.WING
LENGHT/WEIGHT
(m)
(Kg)
2
300
2
300
2
300
2-4
300/500
5-2
300/800
3,5
300
2
300
ENGLISH
STROKE
MANOEUVRES
WORKING/TOT
(mm)
(mm)
24h
270
290
500
270
290
500
270
290
500
270
290
350
390
410
250
390
410
500
270
290
500
LUX Ver. 05 -
-1
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lux bLux 2bLux lLux gLux gvLux mb

Table des Matières