Title : Amphenol RET User Guide
Titre :
Manuel d'utilisation des RET Amphenol
Reference : User Guide
3.3 RET manual check
3.3.1 RET with plastic tube
To manually check a Tube RET, the plastic tube need to be removed:
-
Do a counter-clockwise rotation of plastic tube
-
The tube is now unlocked
-
Pull the plastic tube towards you to remove it from the end cap
-
The RET can be now mechanically controlled by rotating the red knob by hand in a clockwise
or counter-clockwise direction
-
If the RET can rotate freely then it is functional
151221BF
Page 6 sur 69