When there is a fault condition the MDCU sends the corresponding alarm. These alarms conform to the AISG standard:
Code
Name
0x02
- Motor Jam
- Actuator Jam
Permanent
- Motor
Permanently
Stalled
0x03
- Actuator Jam
- Actuator Jam
Temporary
- Motor
Temporarily
Stalled
0x05
Busy
0x06
Checksum Error
When does this alarm occur in our RET ?
The transparent tube of the tilt bar has detached
itself during a motor movement
The maximum time to perform the tilt command (set
tilt, calibration) is elapsed (1min30 max), while the
targeted tilt setting has not been achieved.
The MUX board (multi-motor) inside the antenna is
faulty. This board cannot be removed.
The motor or associated components are faulty (open
circuit or short circuit, bad potentiometer, etc.)
Motor runs in the reverse direction
The transparent tube of the tilt bar has detached
before a motor movement
The motor cannot step
A time consuming command (e.g. Calibration, Set Tilt)
is in progress
During a download, the checksum of a line of the file
being downloaded is bad.
What can you do ?
Check whether the transparent tube is in place
Check whether something prevents the tilt bar
from moving – obstruction
Swap the RET/MDCU
Change the antenna
Check whether the transparent tube is in place
Check whether something prevents the tilt bar
from moving – obstruction
Swap the RET/MDCU
Change the antenna
Wait until the command is complete.
If the problem persists longer than 3 minutes and
no command is in progress, do a hard reset
(disconnect the AISG cable, reset the BTS, etc.)
Swap the RET/MDCU
Request the latest version of firmware.