1.3.5 Maintenance and cleaning

The device does not require maintenance. Opening the device voids the warranty. The inside
of the unit can only be cleaned by the manufacturer.
Do not immerse or spray the device. Avoid that liquid enters the device.
To clean the device exterior:
1. Decommission the device (see chapter 1.3.4 "Decommissioning").
2. Casing: Clean with isopropanol or similar cleaning solution.
Caution
3. Protective grill on fan: Clean with a dry brush.

1.3.6 Disassemble

Only professional staff who are qualified in electrical engineering are allowed to disassemble
parts of the system.
1. Decommission the device (see chapter 1.3.4 "Decommissioning").
2. Remove the connectors. Disconnect the potential earth connection last.
3. Demount: loosen the fastening screws. Remove the device.

1.3.7 System Repair

Only professional staff who are qualified in electrical engineering are allowed to exchange
parts of the drive system.
CAUTION
tiple episodes may occur.
Work on the electrical installation may only be performed by trained and qualified per-
sonnel, in compliance with the regulations for safety at work, and only with use of pre-
scribed personal safety equipment.
Exchange of PCMM
Only the manufacturer can repair the device. Opening the device voids the warranty.
1. Decommission the device (see chapter 1.3.4 "Decommissioning").
2. Demount the device (see chapter 1.3.6 "Disassemble").
3. Send the device to the manufacturer.
4. Install a new device as described in this manual.
5. Setup the system as described in this manual.
Exchange of other drive system parts
If parts of the drive system ( for example cables) must be replaced, proceed as follows:
1. Decommission the device (see chapter 1.3.4 "Decommissioning").
2. Exchange the parts.
3. Check all connections for correct fastening.
4. Setup the system as described in this manual.
: Highly Flammable! Risk of injury by explosion and fire.
Observe the safety notes given on the cleaning liquid package.
Wait at least 30 minutes after cleaning before putting the device back into oper-
ation.
: Automatic Start! During replacement work a combination of hazards and mul-
PCMM Installation Manual | 1   English
Kollmorgen | kdn.kollmorgen.com | February 2018
9

Publicité

Table des Matières

Dépannage

loading

Ce manuel est également adapté pour:

903-300000-99PcmmAkc-pcm-m serieAkc-pcm-mx

Table des Matières