1.6.6 Motion Bus Interface (X6)
Do not connect the Ethernet service cable for the PC to the motion bus interface X6. The Eth-
ernet service cable must be connected to X32.
Connector
1.6.7 Rotary Switch (RS1)
You can use the rotary switch RS1 to set the IP address of the PCMM. The configured IP
address (depending on the current rotary switch RS1 position) will be displayed on the 7 seg-
ment at Ethernet cable connection time and at power-on, if an Ethernet cable is connected. If
no Ethernet cable is connected, no IP address will be indicated in the display.
Rotary Switch Setting PCMM IP Address
The PC subnet mask must be set to 255.255.255.0 or 255.255.255.128
18
Kollmorgen | kdn.kollmorgen.com | February 2018
LED#
Color
X6
LED3
Green
LED4
Yellow
0
DHCP/AutoIP address. The IP address of the device is obtained
from the DHCP server on your network. If no DHCP server is
found the IP addresses is an AutoIP address (it is internally gen-
erated following the AutoIP protocol and will be of the form
169.254.xx.xx).
1
Static IP Address. The IP address is software configurable from a
web-browser. The default IP address at switch position 1 is
192.168.1.101. To configure the IP address, open a web browser
and type the IP address in the URL box. The PCMM web page will
appear. Navigate to the Settings tab and then the Network tab to
configure the static IP address for the PCMM.
2 to 9
Static IP Address. The IP address is 192.168.0.10n, where n is the
number from the rotary switch. This setting generates addresses in
a range from 192.168.0.102 to 192.168.0.109. Example:if RS1 is
set to 5 – the IP address is 192.168.0.105