PCMM Installation Manual | 1 English
1.3 Handling
1.3.1 Transport
Transport the PCMM in accordance with IEC 61800-2 as follows:
Transport only by qualified personnel in the manufacturer's original recyclable packaging.
Avoid shocks while transporting.
Store at or below maximum stacking height of 8 cartons.
Transport only within specified temperature ranges:
-25 to +70 °C, max. rate of change 20 K/hour, class 2K3.
Transport only within specified humidity:
max. 95% relative humidity, no condensation, class 2K3.
The PCMM contain electro-statically sensitive components that can be damaged by incor-
rect handling. Electro-statically discharge yourself before touching the PCMM. Avoid con-
tact with highly insulating materials, such as artificial fabrics and plastic films. Place the
PCMM on a conductive surface.
If the packaging is damaged, check the unit for visible damage. Inform the shipper and the
manufacturer of any damage to the package or product.
1.3.2 Packaging
The PCMM packaging consists of recyclable cardboard with inserts and a label on the out-
side of the box.
Packaging dimension (HxWxL): 107 mm x 268 mm x 220 mm
Total weight: 1.2 kg
1.3.3 Storage
Store the PCMM in accordance with IEC 61800-2 as follows:
Store only in the manufacturer's original recyclable packaging.
Store at or below maximum stacking height of 8 cartons.
Store only within specified temperature ranges: -25 to +55 °C, max.rate of change
20 K/hour, class 1K4.
Storage only within specified humidity: 5 to 95% relative humidity, no condensation, class
1K3.
1.3.4 Decommissioning
Only professional staff who are qualified in electrical engineering are allowed to decom-
mission parts of the system.
8
Kollmorgen | kdn.kollmorgen.com | February 2018
Switch off the main switch of the switchgear cabinet.
Secure the system against restarting.
Block the main switch.