Static IP addressing
When connecting the PCMM directly to a PC, static IP addressing must be used. Set rotary
switch RS1 to a number from 2 to 9 (see table above)
Dynamic IP addressing (DHCP and Auto-IP)
With RS1 set to 0, the PCMM is in DHCP mode. The PCMM will acquire its IP address from
an external DHCP server if present in the network. If a DHCP server is not present, the
device will assume an Automatic Private IP Address of the form 169.254.x.x.
If your PC is directly connected to the device, and set to obtain an IP address automatically
in the TCP/IP settings, a connection will be established with both devices using compatible
automatic generated addresses. It can take up to 60 seconds for a PC to configure an Auto-
matic Private IP Address (169.254.x.x).
Changing the IP address
If the switch is altered while 24 V Logic power is supplied to the PCMM, you must switch off
and then switch on again the 24 V supply voltage. This action will reset the address.