Programming decelerations
So as to fully meet the compliance requirements established by European Standards EN 12445 and EN 12453 on matters concerning
maximum impact forces, BX-74/78 is set up for deceleration at 50 cm from the opening and closing endpoints. When installing all you need to
do is program the gate operation as follows:
Before proceeding, set all the DIP SWITCHES to OFF (10-way Dip Switches)
a) - Set Dip Switch 4, 7, 8 and 9 to ON (10-way Dip Switch) and Dip Switch 3 e to OFF (4-way dip-switch, optical reader);
b) - press CH1 until the red LED starts fl ashing (after about 3 secs). After which, the gate will fully open and close.
c) - when the led stays on, this means the programming procedure is fi nished;
d) - reset the DIP SWITCHES to the previous setting, which is determined by the selection of functions.
The decelerated gate operation speed may be changed by simply pressing CH1 (to reduce it) or CH2 (to increase it) while the operator
is decelerating.
NOTE: When the card is initially activated, the PROG LED will fl ash rapidly, and in so doing signalling that the card is not programmed; once
programmed the LED will remain off.
To exclude decelerations, set Dip Switch 10 to ON.
If power is cut off during gate closure operation and decelerations have been activated, once the power comes back on, the operator always
and for safety reasons, will perform a full, decelerated opening and closing cycle.