Maintenance and cleaning

The filter system is self-cleaning. Dead biomass drops to the bottom and has to be removed. To do this, open
the DN 75 dirt outlet for approx. 10 seconds.
 The entire filter system only needs to be taken out of operation for cleaning and maintenance if it is ex-
tremely soiled.
 Do not use any chemical cleaning agents as they would kill the filter bacteria.
How to proceed:
1. Switch off all filter pumps.
2. Switch off all other electrical units of the filter system (e.g. UVC clarifier).
3. Gravity fed systems only: Close the slide valves (supply and return) of the filters connected in series to pre-
vent further water flow.
4. Open the slide valve for the DN 75 dirt outlet at the bottom of the container and dispose of the soiled water
in a permissible way.
5. Carry out cleaning measures.
– Rinse the Hel-X bio-elements in the container with running water.
6. Close the slide valve (dirt outlet).
7. Start up the filter system again. (→ Commissioning/start-up)
8.1

Replace the aerator rod

How to proceed:
 I
1. Remove approx. 2/3 of the Hel-X bio-elements and keep moist. After completing the maintenance
measures, return the Hel-X bio-elements to the container.
2. Pull the aerator rod out of the clamping holder at the bottom of the container.
3. Disconnect the hose from the aerator rod and fit it onto the new aerator rod.
4. Press the new aerator rod into the clamping holder.
9

Storage/Over-wintering

The unit is protected from frost:
The unit can be operated as long as the water temperature does not go below +4 °C.
The unit is not protected from frost:
Take the unit out of operation at water temperatures below +8° C or, at the latest, when freezing temperatures
are to be expected.
 Drain the unit as far as possible, clean thoroughly and check for damage.
 Empty all hoses, pipes and connections as far as possible.
 Leave the slide valves open.
 Cover the filter container to prevent the penetration of rain water.
 Protect pipes and slide valves that are in contact with water from frost.
10

Disposal

Support us in our endeavour to keep our environment intact, and adhere to the following disposal information!
Dispose of the unit in accordance with the national legal regulations.