Functional Description - Black & Decker BV3600 Manuel D'instructions

Masquer les pouces Voir aussi pour BV3600:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Rules and Instructions: Extension Cords
Double insulated tools have 2-wire cords and can be used with 2-wire or 3-wire
extension cords. Only round jacketed extension cords should be used, and we
recommend that they be listed by Underwriters Laboratories (U.L.) (C.S.A. in Canada).
If the extension will be used outside, the cord must be suitable for outdoor use. Any
cord marked as outdoor can also be used for indoor work. An extension cord must
have adequate wire size (AWG or American Wire Gauge) for safety, and to prevent loss
of power and overheating. The smaller the gauge number of the wire, the greater the
capacity of the cable, that is 16 gauge has more capacity than 18 gauge. When using
more than one extension to make up the total length, be sure each individual extension
contains at least the minimum wire size. Before using an extension cord, inspect it for
loose or exposed wires, damaged insulation, and defective fittings. Make any needed
repairs or replace the cord if necessary.
To determine the
Volts
minimum wire size
120V
required, refer to
Ampere Rating
the chart:
More Not more
Than Than
0
-
6
6
-
10
Safety Rules and Instructions: Polarized Plug
To reduce the risk of electric shock, this equipment has a polarized plug
(one blade is wider than the other). This equipment must be used with a
suitable polarized 2 wire or 3 wire extension cord. Polarized connections
will fit together only one way. Make sure that the receptacle end of the
extension cord has large and small blade slot widths. If the plug does
not fit fully into the extension cord, reverse the plug. If it still does not fit,
obtain a suitable extension cord. If the extension cord does not fit fully into
the outlet, contact a qualified electrician to install the proper outlet. Do not
change the tool plug or extension cord in any way.
Minimum Gauge for Cord Sets
Total Length of Cord in Feet
0-25
26-50
51-100 101-150
American Wire Gauge
18
16
16
18
16
14
The label on your tool may include the following symbols:
V ....................volts
Hz...................hertz
min.................minutes
or DC...direct current
..................double insulated
..................safety alert symbol
.................... Read instruction manual before use
......................... Use proper respiratory protection
......................... Use proper eye protection
......................... Use proper hearing protection
1. On / Off Switch
2. Power head
3. Upper blow tube
14
4. Lower blow tube
12
5. Concentrator
6. Upper vac tube
7. Lower vac tube
8. Shoulder bag
4
A ..........................amperes
W .........................watts
or AC ..............alternating current
n o .........................no load speed
.........................earthing terminal
.../min or rpm...revolutions or

FUNCTIONAL DESCRIPTION

3
6
4
7
5
reciprocation per minute
2
1
8

Publicité