(DIS)CONNECTING THE INDOOR AND OUTDOOR UNIT
(FOR QUALIFIED PERSONNEL ONLY)
DISCONNECTING
1
2
3
4
5
6
7
8
CONNECTING
1
2
3
4
4
78
NOTE!
When the air conditioner is in use, under normal circumstances the
condensed water will be discharged through the outdoor unit
Switch off the unit, remove the plug from the mains and leave it idle for at
least 30 minutes.
Open the cabinet cover for quick connector shielding µ.
Disconnect the electric cable.
Disconnect the drain tube.
Remove the isolation material from the connectors.
Remove the metal brackets which are holding the tubes and wire.
Disconnect the refrigerant tubes using the spanners ¹ provided. The
terminals are fitted with automatic self-sealing valves to prevent the
refrigerant from leaking. Loosen the nuts quickly, so the seal is made
promptly. During the operation take extreme care not to break or bend the
refrigerant tubes.
Screw the protection caps for the connectors
refrigerant tubes connectors.
IMPORTANT
• Never store the indoor/outdoor unit disconnected.
• Do not operate the indoor unit if the quick-connectors are
disconnected. This might cause harm to people and property.
Pass the connection tube through the hole (at least Ø 50 mm) in the wall.
Remove the protection caps from the ends of the refrigerant tubes.
Reconnect the refrigerant tubes according to the marking (tighten the nuts
quickly to make a good seal), the drain tube and the electrical cable.
Put back the metal brackets which are holding the tubes and wire.
.