1.11 Failure possibilities and causes
Impossible to use the keys:
• Key lock input activated
Counter does not count:
• Wrong or reversed wiring of the counting input
• Setting of an input signal not matching the pulse gen-
erator
• Polarity (NPN/PNP) reversed
• No ground connection between the pulse generator
and the counter
• Maximum counting frequency exceeded
• Signal levels do not reach the switching threshold of
the counter
Overview
Model
Operating mode
6.130.012.8x0
Count
6.130.012.8x2
6.130.012.8x3
6.131.012.8x0
Cnt.Dir/Up.Dn
6.131.012.8x1
6.131.012.8x3
Up.Dn
6.132.012.8x3
Cnt.Dir
6.133.012.8x0
Quad/Quad2
6.133.012.8x1
Table 1
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A:
Counting input
INP B:
Counting direction input
Up.Dn:
Differential counting input
INP A:
Adding counting input
INP B:
Subtracting counting input
Quad:
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Quad2:
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce a
possibly existing defect and to repair your device as
quickly as possible.
Counting inputs
INP A
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
Options:
AC input modes:
Count:
Cnt.Dir:
Up.Dn:
INP B
07 kHz
00 ... 0,7 V DC
12 kHz
00 ... 0,7 V DC
30 Hz
10 ... 260 V AC/DC
07 kHz
00 ... 0,7 V DC
12 kHz
04 ... 30 V DC
30 Hz
10 ... 260 V AC/DC
30 Hz
10 ... 260 V AC/DC
03 kHz
00 ... 0,7 V DC
06 kHz
04 ... 30 V DC
x = 5: no backlight
x = 6: with backlight
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input
NPN
30 Hz
NPN
AC/DC
0–
NPN
07 kHz
PNP
12 kHz
AC/DC
30 Hz
AC/DC
30 Hz
NPN
03 kHz
PNP
06 kHz