Power Up; Operation; Default - Factory Settings - Macurco RD-12 Instructions D'utilisation

Masquer les pouces Voir aussi pour RD-12:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Power Up

The RD-12 steps through an internal self-test cycle for the first minute that it is powered. The unit will execute the test cycle any time
power is dropped and reapplied (i.e. power failure). During the self-test cycle the unit will display the firmware version number, then
count down from 60 to 0 (if the display option is "on") and finally go into normal operation. The alarm relay will be activated for 10
seconds and the fan relay for 60 seconds during the power-up cycle unless the "Power Up Test" (PUt) option is OFF. The indicator light
(LED) will flash green during the self-test cycle. At the end of the 1 minute cycle, the unit will take its first sample of the air and the
indicator light will turn solid green.

Operation

1.
With the display function turned "On", the RD-12 will show the current concentration of refrigerant gas ppm or "0" (zero) in clean
air. When the gas concentration reaches the Fan Relay setting (100 ppm, for example) the display will flash back and forth
between "FAn" and "100". With the display function turned "OFF", the display does not show the refrigerant gas concentration,
but will show "FAn" as long as the fan relay is activated.
2.
With the display function turned "On" and the refrigerant gas concentration reaching the Alarm Relay setting, (200 ppm, for
example) the display will flash back and forth between "ALr" and "200". The buzzer will sound indicating "Alarm" if the buzzer is
turned "On". With the display function turned off the display does not show the refrigerant gas concentration, but will show "ALr"
when the Alarm relay is activated.
3.
With the 4-20 mA function turned "On" and the refrigerant gas concentration climbing, the 4-20 mA signal will ramp up
corresponding to the concentration (0-300 ppm, for example). The display will show "FAn" and "ALr" and sound as outlined
above.
Default Configuration – Factory Settings
The default Power Up Test setting is ON
The default Display setting is ON
The default Buzzer setting is ON
The default Alarm Relay Setting is activation at 300 ppm
The default Alarm Relay Configuration setting is Normally Open
The default Fan Relay Setting is activation at 100 ppm
The default Fan Relay Delay setting is 3 minutes
The default Fan Relay Minimum Runtime setting is 0 minutes
The default Fan Relay Latching condition is OFF
The default Trouble Fan Setting condition is OFF
The default 4-20mA Output setting is ON
To change settings, remove the Philips screw on the front of the RD-12. Pull off the front cover of the unit.
12

Publicité

Table des Matières
loading

Table des Matières