Lasersources: aircooled DPSS laser (blue with RGB models, green all models), laser diode (red with RGB
models)
Laser class: 4
Modes: ILDA, DMX 512, auto
ILDA: ILDA standard Sub-D shaped 25pin connector
Galvos: max 50k scanspeed (at 4°)
DMX 512: 18 channels
Patterns: 160
Scanangle: set to ca. 40° optical (60° max)
Input voltage: AC 110-120, 220-240V switchable
50/60Hz
Power consumption: 350W
Size: 675 x 370 x 420mm (W x D x H)
Weight: 30kg Laser, total: 55kg (with
flightcase)
Operating temperature: 10°-35°C
Loudness: <70db
Change scanner
1. Unscrew UK M6 screws and disconnect signal
cable.
2. Loosen M4 x 10 screw and remove galvo.
3. Insert galvo, reconnect and fix signal cable.
4. Rotate galvo to center projection. Fix galvo.
Adjustable mirror mounts
Loosen setscrews, then adjust with X/Y adjustable screws. Make
sure beam is centered on scanner mirrors. Adjust Z-screw
simultaneously Tighten setscrews.
Pro-700 RGB: use tool (screwdriver) and give slight blow with
hand, to adjust mounts.
When combining beams (RGY/RGB laser), first make sure the beams
are (roughly) on the same spot on the mirrors/dichros. Then use a
test pattern (e.g. rectangle) to do fine adjustment. For adjustments,
always turn output power down (if possible).
Troubleshooting
Problem
No power
X and/or Y axis no
deflection
Laser dark or dim
No output
Laser does not switch to ILDA mode:
 The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface manual
 The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
 Use an adapter, that connects pins 4 and 17.
Possible reason
Fuse blown
Power supply defective
CPU defective
Scanner defective
CPU defective
Control board defective
Power supply defective
Scanner driver board defective
Lenses / mirrors dirty
Laser diode defective
Control board defective
Configuration / wrong mode
Configuration / wrong mode
Control board defective
Power supply defective
Display board defective
Pins 4 and 17 of the ILDA signal
not connected
Damaged part
Fuse
+-24V
IC
Galvo
IC
Control PCB
+-24V
Scanner driver board
Clean with alcohol
Laser diode
Control board
Check configuration (see
paragraph control panel)
Check configuration (see
paragraph control panel)
Control PCB
+-24V
Display
See below
5 / 14
Replacement
09-00-3001-01
16-03-0039-00
00-89C516RD-00
15-01-2215-00
00-89C516RD-00
26-2A-LT12V2-00
16-03-0039-00
26-2A-6800A-00
Inquire
26-2A-LT12V2-00
26-2A-LT12V2-00
16-03-0039-00
26-2A-YX2012DI-00
Revision: Apr-10