Kohler K-98741 Guide D'installation Et D'entretien page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2x6
Power Data Supply
2x6 Stud Cavity
10. Install the PDS
WARNING: Risk of electrocution. Disconnect the electricity
to the working area at the main breaker panel before
performing the installation steps for hardwiring.
The PDS is designed to fit within a service closet or 2x6 stud
cavity with access panel. The service closet or access panel must
be located less than 30' (9.14 m) from the overhead rain panel.
Recommended maximum distance is 25' (7.62 m).
If mounting boards are required, they should be positioned to
allow adequate surface area to attach the PDS via the existing
mounting holes on both ends of the PDS box.
Route electrical wire to the service closet or 2x6 stud framing,
within 24" (610 mm) of the PDS. Make sure the wire is in a
position to reach the PDS where electrical connections can be
made, and allow enough wire to create a drip loop.
Orient the PDS box within the service closet or access panel to
allow room for cover removal and connecting the cables. If
possible, connect the cables through the side holes rather than
those on the cover to avoid complicated cover removal for
servicing.
Kohler Co.
Position
to far left.
6" (152 mm) Min
Drip Loop
17
Mounting Board
8-1/4" (210 mm)
100-240 VAC
1207716-2-C

Publicité

Table des Matières
loading

Table des Matières