To change wire
1. Unbolt the counterweight tube.
2. Loosen both jubilee clips and push the hose together in the middle of the telescopic tube.
3. Detach the counterweight.
4. Unscrew the bolt holding the hood attachment to the telescopic tube, and remove the hood
attachment carefully. Push the telescopic section together until the old wire comes through
at the lower end.
5. Put the upper end of the new wire through the eye of the old wire. Pull at the upper end of
the old wire until the new wire at the top of the tube. Pull the new wire at the top until the
eye at the lower end is in line with the hole for the bolt. Push the hood attachment onto the
telescopic tube very carefully and fasten the bolt.
6. Tie the new wire to the counterweight as before.
7. Mount the new wire as shown on picture.
8. Re-position the counterweight tube and the hose.