Before doing any action, disconnect the
appliance from the input power.
6) COMPONENTS SUBSTITUTION
To replace the components lodged in the internal
part, is necessary to take the appliance up from
the furniture, overturn it, loosen the screws and
take away the bottom.
After these actions is possible to work on the
plates, commutators, clamps and input cable.
In case of substitution of the input cable, the
installer must keep the "earth" conductor
Denominations
"Hi-light" electric heating element Ø 145 mm
"Hi-light" electric heating element Ø 180 mm
TYPE AND SECTION OF THE POWER CABLES
Cable type
Rubber
H05 RR-F
MAINTENANCE
POWER OF ELECTRICAL COMPONENTS
WARNING: MAINTENANCE MUST ONLY BE
PERFORMED BY AUTHORISED PERSONS.
longer than "live" ones, and must respect the
cautions
in
CONNECTION".
To reassemble the appliance repeat the inverse
process.
7) TECHNICAL CHARACTERISTICS OF
THE ELECTRICAL COMPONENTS
To facilitate the job of the installer we present a
scheme with the characteristics of the
components.
(for 2 or 1 HEATING ELEMENTS)
Single phase power
230 - 240 V ~
3 X 1.5 mm
2
23
paragraph
"ELECTRICAL
W
1200
1800

Publicité