Manual programming

3
2
1
F1
F2
F3
F4
**
Factory setting
**
Programming example
Programming is carried out in four steps, which
are briefl y summarised here.
Start manual programming
1.
Disconnect the power supply — wait at
least 20 s — and reconnect the power
supply.
When the electronics are booting, the LED
in the sensor fi eld fl ashes red/yellow.
Do not put your hands into the sensor
area during this phase!
Afterwards the LED is red for max. 7 s.
During this red phase, cover the sensor
area above the LED and keep it covered.
Programming mode is started.
Select function (F1 - F4)
2.
The functions are now indicated one at a
time by the fl ashing yellow LED (see table).
To select a function, uncover the sensor
area when the corresponding code is
fl ashing.
16
Parameter:
P1
Range
Short
Stagnation
Off *
fl ush
Thermal
Off *
disinfection
Cleaning stop
Off *
In the pictures on pages 17 and 18, manual programming
is depicted step-by-step.
As an example it is shown how to set the "range" func-
tion (F1) to "long" (P3).
3.
4.
Manual programming
Operating elements for programming:
1 Sensor fi eld
2 LED (yellow / red)
3 Upper sensor area
The following table provides an overview
of the main programs and the available
parameters for programming the fi tting
manually:
P2
Medium *
On, 24 h after
last use
On, TD 300 s
On, 60 s
Set parameters
The fl ashing red LED shows you the cur-
rently set parameter (see table).
By covering the sensor area again you
can set the corresponding parameter. The
parameters are indicated one at a time by
the fl ashing red LED (see table).
To set a parameter, uncover the sensor area
when the corresponding code is fl ashing.
Start operation
After leaving the sensor area, the pro-
gramming mode starts once again with a
time window of 7 seconds (red LED is on
continuously).
If the sensor area is not covered during
these 7 seconds, the programming is com-
pleted. The fi tting is now ready for use.
P3
**
Long
On, daily every
24 h
---
---