4.4.2 Wall Sleeve Installation
IOM
IOM
INSTALLATION CREW MUST ADHERE TO ALL LOCAL/NATIONAL SAFE WORK PRACTICES
8.
When installed, the Wall Sleeve must protrude
1/2" MIN. to 1" MAX. beyond the exterior fi nished wall
to allow proper water evacuation through the drain holes
in the bottom panel. See FIG. 8.
9.
Wall sleeve can be installed from inside or outside the
building (FIG. 9). The side and top brackets' position need
to be adjusted to suit the method and building material.
W415-2288 / 08.29.2019
INCLUDING EMPLOYING APPROPRIATE FALL ARREST EQUIPMENT
WARNING
!
8
I N S I D E
9
!
Flashing
Wall Sleeve
Flashing
Install the wall
sleeve into the
wall until the
support brackets
are set on wall
edge.
H68.3.5
Finished Wall
PROTRUDE
1/2" MIN.-1" MAX.
O U T S I D E
PROTRUDE
1/2" MIN.-1" MAX.