MAINTENANCE AND INSPECTION

5.1. Maintenance

 Check the water supply device and the release often. You should avoid the condition of no
water or air entering into system, as this will influence unit's performance and reliability.
You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the
dirty of clogged filter.
 The area around the unit should be dry, clean and well ventilated. Clean the side heating
exchanger regularly to maintain good heat exchange as conserve energy.
 The operation pressure of the refrigerant system should only be serviced by a certified
technician.
 Check the power supply and cable connection often. Should the unit begin to operate
abnormally, switch it off and contact the qualified technician.
 Discharge all water in the water pump and water system,so that freezing of the water in
the pump or water system does not occur. You should discharge the water at the bottom of
water pump if the unit will not be used for an extended period of time. You should check
the unit thoroughly and fill the system with water fully before using it for the first time after
a

5.2. Trouble Shooting

Malfunction
Water inlet temp. Sensor failure
Water outlet temp. Sensor failure
Ambient temp. Sensor failure
Pipe temp. Sensor failure
Evaporator temp. Sensor failure
High pressure protect
Low pressure protect
Flow switch failure
Temp. is too much different
between water-inlet and outlet
Antifreezing under cooling mode
The primary anti-freezing
protection start.
The second anti-freezing
protection start
Communication failure
Display
The water inlet temp. Sensor is open or
P01
short circut
The water outlet temp. sensor is open or
P02
short circuit
The ambient temp. sensor is open or
P04
short circuit
The pipe temp. sensor is open or short
P05
circuit
The evaporator temp. Sensor is open or
P07
short circuit
The exhaust pressure is high, high
E01
pressure switch action
The suction pressure is low, Low
E02
pressure switch action
E03
No water or litter water in water system
Water flow volume not enough, Water
E06
system pressure difference is small
E07
Water flow volume not enough
E19
Ambient temperature is too low
E29
Ambient temperature is too low
Communication failure between remote
E08
wire controller and main board
17
Canse
Check or change the water inlet temp.
Sensor
Check or change the water outlet
temp. Sensor
Check or change the ambient temp.
Sensor
Check or change the pipe temp.
Sensor
Check or change the evaporator temp.
Sensor
Check high pressure switch and
cooling return circuit
Check low pressure switch and
cooling return circuit
Check the flow volume, water pump is
failure or not
Check the flow volume, water system
is jammed or not
Check the flow volume, water system
is jammed or not
Check the wire connection between
remote wire controller and main board
Solution