240 VAC Source
N
L1
Line Neutral
(White Curly Wire)*
Equipment Ground*
Neutral
Bus
*Connections at the Circuit Breaker
4. Make Electrical Connections – Latin America
NOTE: The electrical rating of the product is printed on a label on the lumbar end of the bath. The bath
with heated surface is designed to operate between 110 V and 240 V at either 50 Hz or 60 Hz.
WARNING: Risk of electric shock. Disconnect the power before performing the following
procedures.
WARNING: Risk of electric shock. Connect the bath to a properly grounded Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD) for protection against line-to-ground
shock hazard.
IMPORTANT! The white wire should be connected to the load neutral terminal on the GFCI or RCD
breaker. The green wire is the equipment ground and must be connected to the neutral bus in the main
circuit breaker box.
Follow local electrical codes. Bond in accordance with local codes.
Remove the 120 V plug from the electrical cord on the junction box mounted to the control board.
Connect service to the junction box with a 240 V plug (not included) or hardwire connection. The
junction box contains black, white, and green colored wires and a ground lug.
Kohler Co.
Breaker Box
Typical Single-Pole
Circuit Breaker
with GFCI
Typical 240 V Wiring Connection
Bond in accordance with local codes.
240 V
Load Neutral
Field Wiring
(From Junction Box
to Breaker Box)
7
Junction
Wire Connector
Box
Black
(L1)
Provide suitable strain relief.
Green
(Ground)
From Control
White
(Neutral)
1196030-2-B