Maintenance And Cleaning - Oase AquaMax Eco Gravity 10000 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
- EN -
to a water line. Use the enclosed adapter set to ease tube (6) or hose (7) installation. When fitting the tube, ensure
that the unit is installed without any tension.
Submerged installation (A)
At the pressure socket (2), connect the line returning the water into the pond. When submerged, insert the unit into the
filter module. Ensure that the unit never runs without water flowing through! Maximum installation depth: 4 metres.
Dry installation (B)
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Remove the contact pro-
tection (3) by turning it counter-clockwise. Do not reach into the pump opening (1). If necessary, fasten the suction
hose using the adapter set provided for tube (6) or hose (7) installation. Connect the suction hose to the suction socket
(1).
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Commissioning/start-up
N O T E
Prevent the pump from running dry. Otherwise the pump will be destroyed.
• Only operate the pump when it is immersed.
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
• Do not connect the unit to a dimmable power supply.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the unit
N O T E
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Dry run/blockage protection
The unit switches off automatically if it runs without water or if the impeller unit is blocked.
– Check that the unit is below the water line and that it does not run dry or take in air during operation.
– If the impeller unit is blocked, pull the power plug first and ensure that the unit cannot be switched on unintention-
ally. Turn the contact protection counter-clockwise or unscrew the screw-connection of the suction line. Over-
come the cause of the blockage through the pump opening. Refit the contact protection or retighten the screw-
connection. Restore the power connection and put the unit into operation.
– This switch-off function is reset by pulling the power plug.
S
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquamax eco gravity 15000Aquamax eco gravity 20000

Table des Matières