Oase AquaMax Eco Gravity 10000 Notice D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Malfunctions
Malfunction
The unit is not operating
Unit delivers very little or not at all
Storage/overwintering
The unit is frost-proof to -20 °C. If lower temperatures are expected, the unit must be removed and put into storage.
How to correctly store the unit:
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
• Protect electrical connections from moisture and dirt.
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
Replacing the impeller unit
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Turn the contact protec-
tion counter-clockwise or unscrew the screw-connection of the suction line. Undo the 4 screws from the motor block
which fix the pump housing. Pull the impeller unit out of the motor block by overcoming a slight resistance, then replace
it with a new impeller unit. Refit and securely tighten the pump housing. Refit the contact protection or retighten the
screw-connection. Restore the power connection and put the unit into operation. Only use original OASE spare parts.
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Wear parts
• Impeller unit
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Cause
No power supply
Defective fuse
FI switch tripped
Pump rotor blocked
Strainer not covered by water
Slide valve closed
Air pocket in the system
Contact protection clogged
www.oase-livingwater.com/spareparts
Remedy
Check power supply
Check fuse and replace, if necessary
Check switch system and connection cable
Check rotor for blockages and remove if found
Check water level and position of the pump
Check the hose system
Check the hose system
Check and clean