Preparing the Ceiling Cutout
and Housing
The unit must be mounted to the surrounding housing.
See "Installation Considerations" on page 7 for
suggestions on determining hood height.
When calculating the load for the housing support system,
be sure to include the weight of the ventilation unit. See
"Unit Weight" on page 7 for unit weight.
Build housing in accordance with the dimensions noted in
"Ceiling Cutout and Supporting Stud Housing
Dimensions".
For optimal performance, the hood should be mounted
flush against the back wall. In such installations, the rear
trim piece may not be necessary.
For installations of ½'' – 3'' (13 – 76 mm) from the back
wall, the rear trim piece can be used.
Ceiling Cutout and Supporting Stud
Housing Dimensions
inches (mm)
1½'' x 3½'' x 27-13/16''
1½'' x 3½'' x 27-13/16''
(38 x 89 x 707)
(38 x 89 x 707)
"
11/
11/ 16
12
12
16
0-3''
0-3''
(322)
(322)
(0-76)
(0-76)
5
5
17
17
/
/
8
8
"
"
(448)
(448)
16" (407)
16" (407)
Page. 13
1½'' x 3½'' x 23⅜''
1½'' x 3½'' x 23⅜''
(38 x 89 x 594)
(38 x 89 x 594)
⅝'' (16)
⅝'' (16)
56¼"
56¼"
(1,429)
(1,429)
Custom Insert Installation with
Hood Trims
CAUTION
The hood requires at least two people to lift it
safely.
Hidden surfaces may have sharp edges. Use
caution when handling the appliance. Failure
to do so may result in property damage or
personal injury.
WARNING
To avoid electrical shock hazard, before installing,
switch power off at the service panel and lock the
panel to prevent the power from being switched on
accidentally.
1. Turn power OFF at the service panel. Lock service
panel to prevent power from being turned ON.
2. Prepare the ductwork.
a) Refer to "Ductwork Preparation" on page 9.
b) Install metal transition with backdraft damper so
that the flap opens up toward the ceiling. If
necessary, install thermal break and additional
backdraft damper (refer to "Hood Transition" on
page 12).
3. Build the housing framework.
a) Refer to "General Information" on page 6 for the
model dimensions.
b) Refer to "Clearances and requirements" on
page 7 for clearance specifications.
c) Build housing framework for applicable model
according to dimensions in "Preparing the Ceiling
Cutout and Housing" beginning on page 13.