After Use - Dräger Aerotest 5000 Notice D'utilisation

Masquer les pouces Voir aussi pour Aerotest 5000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use
NOTICE
i
i
Do not remove the protective foil of the Dräger Oil-Impactor
until after the measurement has been completed. Observe
the Instructions for Use provided with the products when
using the Dräger-Tubes or the Dräger Oil-Impactor.
Then press the "OK" key to start the test.
displayed as a countdown. The airline pressure, ambient temperature
and the oxygen content are displayed as well.
The status of the individual measurements is indicated on the display.
The spinning hour glasses indicate that the test is being carried out.
The check marks indicate that the tests are complete. Once the test is
complete, the flow control valve must be closed.
Enter the readings from the measurement results of the tubes or the
Impactor into the Dräger Aerotest 5000.
To enter the results press the enter key on the display and use the
numeric display. Then press the
all other values.
Once all results have been entered, press the right arrow key. The
results entered can no longer be altered.
After the test is complete, the display automatically indicates whether
the test was a pass or fail. All measurement values determined during
the test are displayed. If the test was a fail, the criteria that do not fulfill
the standard are indicated by an alternating asterisk. Additionally, the
Dräger Aerotest 5000 automatically calculates the atmospheric
dewpoint. This test result is automatically recorded in the memory of
the Dräger Aerotest 5000. The test results are recorded according to
the date and time at which the corresponding test was completed. Up
to 10 tests can be recorded. To view the test results, select the
"Review tests" menu from the main menu. Previous tests can be
viewed or deleted in this menu.
20
The duration will be
arrow and repeat the process for
To disconnect the Dräger Aerotest 5000 from the air supply to be
tested, make sure that the inlet coupling remains connected to the
Dräger Aerotest 5000 and only disconnect it from the end of the air
supply hose. The adapters can then be removed from the
Dräger Aerotest 5000.
3.4

After use

3.4.1
Exporting test results and PC software.
Recorded test results can be downloaded to the supplied USB stick.
To transfer the results return to the main menu and select the "Export
tests" menu option.
Connect the supplied USB stick to the USB port (11) and confirm the
connection with "Yes".
NOTICE
i
i
If the test to be downloaded is already on the USB stick the
download will fail.
After exporting the data to the USB stick the results can be deleted
from the Dräger Aerotest 5000 memory.
NOTICE
i
i
Before the recorded results can be transferred from the USB
stick to the PC the required software must be installed on the
PC. The software is available on the USB stick.
Once the USB stick is connected to the PC, the software can be
started. Select "Import test results file" from the drop-down menu and
select the corresponding drive. Multiple test results can be imported
after the target drive has been selected.