Transmitter programming procedure
Programming mode is indicated by a brief upwards and down-
wards movement of the drive.
PROG.
Next press the PROG button of the transmitter to be
learnt for a short time.
The new transmitter is now learnt into the receiver.
Note: Programming mode is ended either using a control
command from a transmitter that has been learnt in or as a
result of successful programming.

1.3) Deleting transmitters from the receiver

For this process, at least two transmitters have to already be
learnt into the receiver.
PROG.
To delete a transmitter, press the PROG button of the
3 sec.
transmitter not to be deletet for 3 seconds (wait until
the transmitter control light flashes once). Then the
receiver will be in deprogramming mode for 1 minute.
Deprogramming mode is indicated by a brief upwards and
downwards movement of the drive.
PROG.
Then press the PROG button of the transmitter to be
deleted for a short time. The relevant transmitter has
now been deleted from the receiver.
Note: Deprogramming mode is ended either using a control
command from a transmitter that has been deleted or as a result
of successful deprogramming.
2.) Programming intermediate and ventilation positions
You have the option of learning two positions into the receiver.
2.1) Setting the intermediate position from the upper end limit
To set the intermediate position, move the roller
shutters to the upper end limit.