Before Weighing; Start Weighing - Kerbl 29924 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Weighting

5.1 Before weighing

Whenever possible, please allow the scale to warm up for several seconds after first turning the power on
so that the scale will function properly and accurately.
Error messages:
EEEE: Overload
: Low battery
5.2 Weighing procedures
5.2.1 Press [ON/OFF] to turn on the scale.
When the power is turned on, all display segments appear for a few seconds and „0" will appear on the display.
5.2.2 Select the weighing unit [UNIT].
Press [UNIT] to select a weighing unit „kg"or „lb".
Once the unit has been selected, the selected unit will be displayed next to the weight value.

5.2.3 Start weighing

• Weighing without container: Verify the reading is „0". If not, press [ZERO/TARE] to display „0". Place the items to be weighed on the platform.
When the reading becomes stable, the stable weighing is displayed.
• Weighing with container: Place an empty container on the platform. Wait for the stability indicator to be displayed and press [ZERO/TARE].
Place the objects to be weighed in the container. When the reading becomes stable, the stable weighing displayed.
6. Calibration
If you use the scale for the first time it is calibrated. Because of this it's not necessary to calibrate it once again.
You can re-calibrate the scale if it goes under environmental influences like dust or dirt.
How to calibrate? (Warning: Information only for calibration service)
**Calibration may only arrange from accredited calibration laboratory**
1. The scale must be powered OFF. Press and hold [ZERO] first, then press [ON/OFF] while keeping the [ZERO] button depressed and
then releases both keys. The display will show the A/D value (a series of random numbers).
2. Wait for the stable indicator to be displayed. Press [UNIT] the display will show „0SAVE" and then the display will return to the random A/D
value. Place the full load kilograms weight(s) on platform. Wait for the stable indicator to display then press [UNIT], the display will show
„0SAVE". Calibration is complete; remove the weight(s). Turn the scale OFF (Press the ON/OFF key), then turn it back ON and check some
weight readings. If calibration is still incorrect, repeat calibration but try it more slowly.
If calibration is repeatedly incorrect then: 1) Replace the batteries, 2) Try a more stable surface or vibration and interference free location,
3) Be sure there is no static electricity on the scale (use an anti-static spray to remove static electricity)