BEDIENUNGSANLEITUNG/ USER MANUAL/ MANUEL D'UTILISATION
PROBLEM SOLVING
PROBLEM
Machine does not work •
Machine does not work
Operating panel is on
Transparent lid does
not open automatically
Final vacuum is
insufficient
The machine builds up
a vacuum slowly
Version 12.10 Art. 0894552
CAUSE
The plug is not plugged into the wall
socket.
•
The main fuse is burnt.
•
The circuit board fuse is burnt.
•
The control transformer fuse is burnt.
•
The Micro-switch that is activated when
the lid is closed is disordered or faulty.
•
There is an internal malfunction.
•
The gas spring is faulty
•
The set vacuum time is too short.
•
There is too little oil in the vacuum
pump.
•
The extraction hole at the back of the
vacuum chamber is partially covered by
the vacuum bag during extraction
•
The lid gasket is worn.
•
The oil is contaminated
•
The oil exhaust filter is saturated.
•
The pump's extraction filter is blocked.
•
The oil exhaust filter is saturated.
SOLUTION
•
Plug the plug into the wall socket.
•
Replace the fuse (Ensure the correct
value).
•
Consult the supplier.
•
Check this and if necessary replace it.
•
The Micro-switch must be properly
adjusted or replaced
•
Consult the supplier.
•
Consult the supplier.
•
Extend the vacuum time.
•
Check the oil level and top up if
necessary (Note the type and quantity).
•
Place the vacuum bag closer to the
sealing beam.
•
Replace the lid gasket.
•
Replace the oil (Note the type & amount).
•
Replace the oil exhaust filter / Consult
the supplier.
.
•
Consult the supplier.
•
Replace the oil exhaust filter / Consult
the supplier.