PROBLEM
Machine does not work •
Machine does not work
Operating panel is on
Transparent lid does
not open automatically
Final vacuum is
insufficient
The machine builds up
a vacuum slowly
Version 12.10 Art. 0894552
CAUSE
The plug is not plugged into the wall
socket.
The main fuse is burnt.
The circuit board fuse is burnt.
The control transformer fuse is burnt.
The Micro-switch that is activated when
the lid is closed is disordered or faulty.
There is an internal malfunction.
The gas spring is faulty
The set vacuum time is too short.
There is too little oil in the vacuum
pump.
The extraction hole at the back of the
vacuum chamber is partially covered by
the vacuum bag during extraction
The lid gasket is worn.
The oil is contaminated
The oil exhaust filter is saturated.
The pump's extraction filter is blocked.
The oil exhaust filter is saturated.
SOLUTION
Plug the plug into the wall socket.
Replace the fuse (Ensure the correct
value).
Consult the supplier.
Check this and if necessary replace it.
The Micro-switch must be properly
adjusted or replaced
Consult the supplier.
Consult the supplier.
Extend the vacuum time.
Check the oil level and top up if
necessary (Note the type and quantity).
Place the vacuum bag closer to the
sealing beam.
Replace the lid gasket.
Replace the oil (Note the type & amount).
Replace the oil exhaust filter / Consult
the supplier.
.
Consult the supplier.
Replace the oil exhaust filter / Consult
the supplier.