7. Vacuum meter
Displays the pressure in the vacuum chamber.
8. ON/OFF Switch
The ON/OFF switch is used to turn the machine on and off before and after operation. The switch turns on all units in the
machine. Caution, the switch does not completely remove all power from the machine.
CONTROL PANEL USE
When the machine is turned on it is ready for use once the two operating codes have displayed.
Description of the program cycle for digital time control
1. Functions (vacuum and sealing) are set with the correct values (see page 13 for settings)
2. Close the lid.
3. Vacuum function
4. Sealing function
5. Ventilating function
6. The product is packed and ready to remove.
Version 12.10 Art. 0894552
The machine starts to vacuum the chamber.
The light in front of [VACUUM] goes on.
Display : decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts increasing to the left.
Once the vacuum function is finished, the sealing function starts to seal the vacuum bag(s).
The light in front of [SEAL] goes on.
Display : decrementing time per 0.1 second starting at the time set (max. 6.0 sec.).
The reading on the vacuum meter stays the same.
After ending the seal function the ventilating function starts ventilating the chamber to 1
atmosphere/ATO and the lid opens.
There are no longer any lights on in front of the functions.
Display : lines moving up and down until the lid is opened.
The vacuum meter runs back to the right to zero and the lid opens automatically.