TIME SERVER CONNECTION STATUS
After the console has connected to the internet, it will
attempt to connect to the internet time server to obtain
the UTC time. Once the connection succeeds and the
console's time has been updated, the "
appear on the LCD.
ADVANCE SETTING IN WEB INTERFACE
Press "ADVANCED" key at the top of web interface to enter the advance setting page, this page
allow you to set and view the calibration data of the console, as well as update the firmware
version on PC web browser.
Press "SETUP" icon to
Setup page
Select setting unit
Outdoor and Ch 1~7
temperature calibration
section
Pressure calibration
section
Current firmware
version
CALIBRATION
1. User can input the offset and/or gain values for different parameters while current offset and
gain values are shown next to their corresponding blank.
2. Once completed, press
The current offset value will show the previous value that you entered, please input the new value
in the blank if any changes needed, the new value will effective once you press
SETUP page.
" icon will
ADVANCED page
SETUP
Temperature
o
C
Indoor
Current offset: 1
Outdoor
Current offset: -9
CH 1
Current offset: 2
CH 2
Current offset: 3
CH 3
Current offset: 1.2
CH 4
Current offset: -0.2
CH 5
Current offset: -20.1
CH 6
Current offset: 11.5
CH 7
Current offset: 0.2
Range: -20.0 ~ 20.0
o
C
-36.0 ~ 36.0
o
F (Default: 0.0)
Pressure
Absolute Pressure Offset:
Relative Pressure Offset:
Setting Range:
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmHg
Current gain: 0.85
*Rain gain:
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 0.75
*Wind speed gain:
Range: 0.5 ~ 1.5(Default: 1.00)
Current offset: 2
*Wind direction:
Range: -10 ~ 10(Default: 0
Current gain: 1.1
*UV gain:
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
*Light gain:
Range: 0.01 ~ 10(Default: 1.00)
* Depends on the model
Firmware version: 1.00
at the bottom of the SETUP page
Apply
ADVANCED
Humidity %
Current offset: -5
Current offset: 10
Current offset: -5
Current offset: -2
Current offset: -2
Current offset: -5
Current offset: -3
Current offset: -10
Current offset: -3
Range: -20 ~ 20
(Default: 0.0)
hpa
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
o
o
)
Browse
Upload
16
Outdoor and Ch 1~7 humidity
calibration section
Select setting unit
Current offset value is the value
that you set before to offset the
pressure reading.
The rain, wind speed, UV and Light
calibration use gain method. The
wind direction is +/- 10 offset.
The firmware update
function only available
in PC web browser
Apply
icon in