Temperatures Available with a Controller
The water heater can deliver water at only one temperature setting at a time. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the "On/Off" button
for 5 seconds while the water heater is OFF.
Fahrenheit °F
Celsius °C
*
Temperature settings from 125-140 °F (52-60 °C) are available by setting SW6 in DIPSW 1 to ON. These
models have a default maximum temperature of 120° F (49° C) and an option (SW6) to increase the
maximum temperature to 140 °F (60 °C).
** These settings require the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91-2 controller in a
residential dwelling will reduce the warranty coverage to that of a commercial warranty application.
WARNING
These temperatures are suggestions only:
Alternate Temperature Settings
A different range of temperature settings is available by setting SW2 and SW3 in the DIPSW 2 to ON. The table
below shows the settings available with the MC-91-2 and MCC-91-2 controller.
WARNING
Fahrenheit °F
Celsius °C
58
Temperature Settings Available
98 100 102 104 106 108 110 115 120
37
38
39
40
DO NOT adjust the other switches unless specifically instructed to do so.
MC-91-1, MCC-91-1, MC-100V-1, and BC-100V-1 controllers are not compatible with
Alternate Temperature Settings. Alternate Temperature Settings are for commercial
applications only.
DO NOT use the MC-91-1, MCC-91-1, MC-100V-1, or BC-100V-1 controllers when SW2
and SW3 in DIPSW 2 are in the ON position.
Alternate Temperature Settings Available
110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185
43
46
49
52
MC-91-2
41
42
43
46
Kitchen
120 °F (49° C)
Shower
98 - 110 °F (37 - 43 °C)
Bath Fill 102 - 110 °F (39 - 43 °C)
54
57
60
63
MCC-91-2
KBD Series Manual
125
130
135
140
*
*
*
49
52
54
57
66
68
71
74
150
160
185
*
**
**
**
60
66
71
85
77
79
82
85