Rated current input
Rated voltage
100 V: 15 A
Rated voltage 120:
15 A
Rated voltage
220 V: 9.9 A
Rated voltage
230 V: 9.9 A
Mains frequency
50...60 Hz
Hammer drilling
360/min
speed
Single impact en-
11.5 J
ergy in accordance
with EPTA proced-
ure 05/2009 (full
power setting)
NOTE
The TE 70‑ATC/AVR and TE 80‑ATC/AVR comply with the applicable standard on condition that the maximum
permitted supply network impedance Z
user's supply network is connected to the public supply network. It is the responsibility of the installer or user of the
equipment to ensure, by consultation with the supply network operator if necessary, that the equipment is connected
only at a point in the supply with an impedance of less than or equal to Z
Other information about the power tool
ATC electronic cut-out
Protection class
NOTE
Noise and vibration information (measured as per EN 60745-2-6): The triaxial vibration value given in this information
sheet has been measured in accordance with a standardized test given in EN 60745 and may be used to compare one
electric tool with another. It may be used for a preliminary assessment of exposure. The declared vibration emission
level represents the main applications of the tool. However, if the tool is used for different applications, with different
accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level
over the total working period. An estimation of the level of exposure to vibration should also take into account the
times when the tool is switched off or when it is running but not actually doing the job. This may significantly reduce
the exposure level over the total working period. Identify additional safety measures to protect the operator from the
effects of vibration such as: Maintaining the machine and insert tools, keeping the hands warm and organizing work
patterns.
Power tool
TE 70-D/AVR
Typical A-weighted
113 dB (A)
sound power level
Typical A-weighted
102 dB (A)
emission sound
pressure level
Uncertainty for the
3 dB (A)
given sound level
Hammer drilling in
10 m/s²
concrete, a
h, HD
Chiseling, a
h, Cheq
TE 70‑AVR
Rated voltage
100 V: 15 A
Rated voltage
110 V: 16 A
Rated voltage
(Taiwan) 110 V: 15 A
Rated voltage 120:
15 A
Rated voltage
220 V: 9.9 A
Rated voltage
230 V: 9.9 A
Rated voltage
240 V: 9.8 A
50...60 Hz
360/min
11.5 J
max is less than or equal to 0.342+j0.25 Ω at the point at which the
max
TE 70‑ATC/AVR, TE 80‑ATC/AVR
Protection class II (double insulated)
TE 70‑AVR
113 dB (A)
102 dB (A)
3 dB (A)
10 m/s²
9 m/s²
TE 70-ATC/AVR
TE 80-ATC/AVR
Rated voltage
Rated voltage
100 V: 15 A
110 V: 16 A
Rated voltage
Rated voltage 120:
110 V: 16 A
15 A
Rated voltage
Rated voltage
(Taiwan) 110 V: 15 A
220 V: 9.9 A
Rated voltage 120:
Rated voltage
15 A
230 V: 9.9 A
Rated voltage
220 V: 9.9 A
Rated voltage
230 V: 9.9 A
Rated voltage
240 V: 9.8 A
50...60 Hz
50...60 Hz
360/min
360/min
11.5 J
11.5 J
.
max
TE 70-ATC/AVR
TE 80-ATC/AVR
113 dB (A)
113 dB (A)
102 dB (A)
102 dB (A)
3 dB (A)
3 dB (A)
10 m/s²
7.5 m/s²
9 m/s²
7 m/s²
en
5