Troubleshooting

11
Troubleshooting
Fault
Cause
The control panel
Starter battery is flat.
does not come on
The fuse (if available) is blown.
when the on/off
switch is pressed.
The starter does
Starter battery is flat.
not work when the
The main switch is at "0".
start button is
pressed.
Internal board is damaged.
Starter is not receiving any power.
The starter turns
No petrol.
but the generator
Too much oil in the engine.
does not start.
Spark plug is not receiving any power.
Carburettor is not receiving any petrol.
Air intake is blocked.
Inverter is damaged.
The generator
Too much oil in the engine.
tends to go off.
Load is over 6,2 kW.
Carburettor is not receiving any petrol.
Air intake is blocked.
Inverter is damaged.
Electromagnet (inverter) is blocked.
Air filter is dirty.
Fuel filter is dirty.
The generator is
Inverter is damaged.
running but does
RPM too low.
not supply any
voltage.
24
Remedy
➤ Charge the starter battery.
➤ Contact an authorised workshop.
➤ Charge the starter battery.
➤ Set the main switch to "I" or "1".
➤ Contact an authorised workshop.
➤ Fill up with petrol.
➤ Drain the oil.
➤ Check the electric connections.
➤ Clean the carburettor.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 22).
➤ Contact an authorised workshop.
➤ Drain the oil.
➤ Switch off the consumers.
➤ Clean the carburettor.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 22).
➤ Contact an authorised workshop.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 22).
➤ Replace the fuel filter.
➤ Check the output wiring
connection
➤ Contact an authorised workshop.