TEC60EV
• Abrupt braking, accelerating and driving round bends in the vehicle can cause
problems in the generator's pump system and lead to unwanted shutdown.
• If you are not using your generator for a longer period of time, start it up at least
every 30 days and leave it running for 15 minutes or more.
8.2
Switching the generator to standby or no function
The generator can be switched to standby or no function with the main switch
(fig. 2 1, page 3) in the connection box.
8.3
Switching the control panel on and off
This switch on the control panel (fig. 3 2, page 4) is for switching the control panel
on and off.
➤ Switch the control panel on with the on/off switch.
✓ The display shows:
The display switches off automatically after 5 minutes if the start button is not
touched within this time.
Press the start button to switch on the display again.
✓ The generator can now be started.
8.4
Starting the generator
The generator can only be started if it is in standby and the control panel is switched
on.
➤ Start up the generator with the grey button "START/STOP" (fig. 3 3, page 4).
8.5
Stopping the generator
➤ Stop the generator with the grey button "START/STOP" (fig. 3 3, page 4).
✓ The inverter shuts down immediately. The engine runs for 30 seconds to cool
down, then the engine stops too.
A
NOTICE! Damage hazard
Always stop the generator with the grey button "START/STOP" to avoid
engine damages. The turn off procedure with the red button has to be
used only for emergency.
EN
GEN OFF
.
Operating the generator
15