Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a minimum 12" (305mm) above grade. The maximum
allowable vent length (including both rise and run) is 10' (3m) for a fi replace and 8' (2m) for a stove. An insulation
sleeve is illustrated in the top vent image below, use only when supplied with the appliance.
(The insulation sleeve is not required with a stove appliance)
REAR VENT

2.2.2 corner termination

The maximum vent length for a corner installation is 24"(609.6mm) of
horizontal run with a minimum 24"(610mm) rise.
minimum venting requirements
30"
(76.2cm) min.
38"
(96.5cm)
TOP VENT
(610mm)
12" (30.5cm)
min. to
grade
8.1
24"
MAX
W415-1596 / B / 10.12.18
EN
11