CAUTION:
equipment away from flames and
heat. Excessive heat will soften
packings and seals, resulting in fluid leaks.
Heat also weakens hose materials and
packings. For optimum performance do not
expose equipment to temperatures of 65°C
[150°F] or higher. Protect hoses and cylinders
from weld spatter.
DANGER: Do not handle pressurized
hoses. Escaping oil under pressure
can penetrate the skin, causing serious
injury. If oil is injected under the skin, see a
doctor immediately.
WARNING:
Only
cylinders in a coupled system. Never
use a cylinder with unconnected
couplers. If the cylinder becomes extremely
overloaded,
components
catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE
BEFORE LIFTING LOAD. Cylinders
should be placed on a flat surface that
can support the load. Where applicable,
use a cylinder base for added stability. Do not
weld or otherwise modify the cylinder to attach
a base or other support.
Avoid situations where loads are not
directly centered on the cylinder
plunger. Off-center loads produce
considerable strain on cylinders and plungers.
In addition, the load may slip or fall, causing
potentially dangerous results.
Distribute the load evenly across the
entire saddle surface. Always use a
saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be
serviced by a qualified hydraulic technician. For repair
service, contact the Authorized ENERPAC Service
Center in your area. To protect your warranty, use only
ENERPAC oil.
WARNING: Immediately replace worn or damaged
parts by genuine ENERPAC parts. Standard grade
parts will break causing personal injury and property
damage. ENERPAC parts are designed to fit properly and
withstand high loads.
3.0 INSTALLATION (Refer to Figure 1)
WARNING: Install proper safety equipment (i.e.,
guards or control devices) as required for your
specific application.
3.1 Press Mounting
DANGER: Mount the press securely. Unstable
positioning may cause the press to tip, resulting in
serious personal injury or equipment damage.
If the press is to be mounted to the floor or some other
foundation, lower press bed to lowest set of holes before drilling
and bolting down. This will ensure that the press does not twist
and that the bed will line up with all sets of holes in the legs.
Keep
hydraulic
use
hydraulic
can
fail
2
6
7
Figure 1, VLP Press Assembly
Item
Description
2
Cylinder
3
Pump
4
Hose
5
* Pump Table
6
Winch Kit
7
Bolster Pin
* Pump table for electrical pumps, PTKESR
3.2 Mounting Pump Table
Attach Pump Table to Upright (use screws, washers and nuts
provided in the kit) by matching mounting hole pattern.
3.3 Securing Pump to Mounting Table
Attach pump to table (use screws, washers and nuts provided in
the kit) by matching mounting hole pattern.
1.
Mount Hand Pump to table at two locations using provided
hardware. See Figure 2.
1 – 5/16-18 x 1.00" long bolts required (Qty. 2)
2
4
3
5
(4) Mounting Hole
Locations
7
Bolster
Model Number / Part Number
VLP256P392
VLP256PAT1
RC256
RC256
P392
PATG1102N
HC9206
HC9206
PTK392SR
PTKPATSR
SPR54015035
SPR54015035
BSS2219D
BSS2219D
VLP256P392
1
Front of press
Figure 2, Hand Pump