Control Access; Rating Plate Information - Napoleon Ascent Linear Série Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Ascent Linear Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

getting to know your appliance
EN
1.1

control access

Access to the control can be done by removing the safety barrier, glass door, door trim and control cover (see
"maintenance" section for instructions on how to remove these components).
1.2

rating plate information

f i r e - p a r t s . c o m
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
note:
The rating plate must remain with the appliance at all times. It must not be removed.
6
W415-1711 / A / 08.27.18
FLAME
ADJUSTMENT
Certified to Canadian and American National Standards: CSA 2.22-2016 / ANSI Z21.50-2016 for Vented Decorative Gas Appliances
Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-2016 / ANSI Z21.50-2016 pour les Appareils à gaz décoratif à évacuation
C
Direct vent, vented gas fireplaces. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the current
standard CAN / CSA Z240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part
3280. When this US Standard is not applicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliance
must be installed in accordance with local codes, if any; if none, follow the current ANSI Z223.1 or CSA B149. For use with barrier W565-0282. Follow installation instructions.
Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installation
conforme aux exigences de la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280,
Manufactured Home Construction and Safety Standard. Dans le cas ou cette norme d'États-Unis n'est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for Manufactured
Home Installations, Sites and Communities. Installer l'appareil selon les codes ou règlements locaux ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1 ou
CSA B149 en vigueur. Utiliser uniquement avec l'écran W565-0282. Suivre les instructions d'installation.
9700539 (WSL)
BL36NT
BL36NTE
Altitude
C
Input
17,500
Reduced Input
12,000
P4
44.1%
Manifold Pressure: 3.5" w.c. (NG)
Minimum Supply Pressure: 4.5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: 3,5" d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 4,5" d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 7"* d'une colonne d'eau (GN)
*Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials:
Sides & back: per stand spacers for framing and finishing
materials. For non-combustible framing and finishing materials,
see installation manual.
Top 0"
Floor 0"
Sides 0"
Back 0"
Vent top 3"
Vent sides & bottom 1"
Recessed depth 16"
Mantel 12"
C
*Maximum horizontal extension: 2". See installation manual for
greater extensions, minimum vent lengths and maximum vent
lengths.
WOLF STEEL LTD.
24 Napoleon Road, Barrie, ON, L4M 0G8 Canada
MAX SIZE: 8.5" X 4.75"
HOLE TO BE 0.250"Ø
Keep burner and control
MATERIAL:
CLASS III
A-2, PERMANENT LABEL, WATERPROOF, 0.010 IN. VELVET MATTE LEXAN AND/OR 0.050 IN. HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUM
compartment clean. See
TEMPERATURE OF 175°F (79°C).
installation and
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2
operating instructions
POINT LEADING SPACING OR EQUIVALENT.
accompanying
BLACK LETTERING ON WHITE BACKGROUND.
appliance. Appliance
SERIAL NUMBERS TO BE ASCENDING FROM BL36 274170
needs fresh air for safe
WOLF STEEL LTD.
operation and must be
installed with adequate
TITLE: LABEL, RATING PLATE
provisions for
combustion and
REVISION:
C: Updated rates + P4 efficiency + added energy efficiency label || 05.29.18_
ventilation air.
S'assurer que le brûleur et
le compartiment des
commandes sont propres.
Voir les instructions
d'installation et
d'utilisation qui
accompagnent l'appareil.
Par mesure de sécurité,
cet appareil doit être
alimenté en air frais et
avec d'air
comburant et de
ventilation suffisant.
MAX SIZE: 8.5" X 4.75"
HOLE IS 0.250"
Ø
/ 0.312 "FROM BOTTOM AND LEFT EDGE"
MATERIAL:
CLASS III
A-2, PERMANENT LABEL, WATERPROOF, 0.010 IN. VELVET MATTE LEXAN AND/OR 0.050 IN. HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUM
TEMPERATURE OF 175°F (79°C).
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2
POINT LEADING SPACING OR EQUIVALENT.
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM
WOLF STEEL LTD.
TITLE:
RATING PLATE C/BL36(N)T(E)-1 / C/BL36(P)T(E)-1
REVISION: C: Updated rates + P4 efficiency + added energy efficiency label || 05.29.18_
VALVE
4001658 (NAC)
4001657 (NGZ)
4001659 (WUSA)
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF
MODEL / MODÈLE
HEAT, NOT INTENDED FOR USE AS A HEATING APPLIANCE,
CBL36NT
CBL36PT
BL36PT
NOT FOR USE WITH SOLID FUEL.
CBL36NTE
CBL36PTE
BL36PTE
APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N'EST PAS
0-4500ft (0-1370m)
Élévation
16,000
Alimentation
UNE SOURCE DE CHALEUR; N'EST PAS DESTINÉ À ÈTRE
12,500
Alimentation Réduite
45.5%
P4
UTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NE
Manifold Pressure: 10" w.c. (P)
CONVIENT PAS AUX COMBUSTIBLES SOLIDES.
Minimum Supply Pressure: 11" w.c. (P)
Maximum Supply Pressure: 13"* w.c. (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
Pression au Collecteur: 10" d'une colonne d'eau (P)
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE
Pression d'Alimentation Min.: 11" d'une colonne d'eau (P)
Pression d'Alimentation Max.: 13"* d'une colonne d'eau (P)
CERTIFIÉES AVEC L'APPAREIL.
*Pression d'alimentation maximale ne devait pas dépasser 13".
WARNING
Dégagements minimaux des matériaux combustibles:
flames, other than that supplied by the manufacturer with the appliance.
Côtés et arrière: selon les espaceurs de dégagements pour les
AVERTISSEMENT
matériaux d'ossature selon le manual du propriétaire pour les
matériaux de finition.
contact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.
Dessus 0"
The appliance must be vented using the appropriate Napoleon vent kits. See installation
Plancher 0"
manual for venting specifications. Proper reinstallation and resealing is necessary after servicing
Côtés 0"
the vent-air intake system.
Arrière 0"
L'appareil doit être ventilé à l'aide de l'ensemble d'évacuation propre à Napoleon. Référez au
Dessus du conduit d'évent 3"
manuel d'installation pour les spécifications d'évacuation. Il est nécessaire de bien réinstaller et
Côtés et dessous du conduit d'évent 1"
resceller l'évacuation après avoir executer l'entertien du système de prise d'air.
Profondeur d'encastré une face 16"
Optional fan kit: AUB
Tablette 12"
Ensemble de ventilateur facultatif: AUB
Electrical rating: 115V, 60HZ. Less than 12 amperes.
*L'extension horizontale maximale: 2". Référez au manuel d'installation
Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.
pour des extensions plus grandes, les longueurs d'évacuation minimaux et
maximum.
Serial Number / N° de Série:
CAUTION:
WARNING:
Improper installation,
adjustment, alteration,
Hot while in operation. Do not touch. Severe
burns may result. Keep children, clothing,
service or maintenance can
furniture, gasoline and other liquids having
cause property damage,
flammable vapors away.
personal injury or loss of life.
ATTENTION:
Refer to owner's manual.
Installation and service must
be performed by a qualified
L'appareil est chaud lorsqu'il fonctionne. Ne pas
installer, service agency or
toucher l'appareil. Risque de brûlures graves.
(C)BL36(N)T(E)-1 / (C)BL36(P)T(E)-1
the gas supplier.
Surveiller les enfants. Garder les vêtements, les
meubles, l'essence ou autres liquides produisant
des vapeur inflammables loin de l'appareil.
AVERTISSEMENT:
Un installation
This appliance is only for use with the type of gas
ou une modification
indicated on the rating plate and may be installed
inappropriée du réglage, du
in an aftermarket, permanently located, manufac-
service et de l'entretien
tured home (USA only) or mobile home where not
pourraient être la cause de
prohibited by local codes. See owner's manual
dommages à la propriété de
for details. This appliance is not convertible for
blessures corporelles ou
use with other gases, unless a certified kit is
même la mort. Consulter le
used.
Cet appareil doit être utilisé uniquement avec le
manuel d'information,
type de gaz indiqué sur la plaque signalétique.
l'installation et le service
Cet appareil peut être installé dans une maison
doivent être exécutés par un
préfabriquée ou mobile (É.U. seulement) installée
installateur qualifié pour le
à demeure si les règlements locaux le permettent.
gaz, un entreprise de
Voir la notice de l'utilisateur pour plus de
service ou le fournisseur de
renseignements. Cet appareil ne peut pas être
gaz seulement.
utilisé avec d'autres gaz sauf si une trousse de
conversion certifiée est fournie.
BL36 274170
Insert
testing
agency
logo
REFERENCE# 161746
:
Do not add any material to the appliance which will come in contact with the
:
N'ajoutez pas à cet appareil aucun matériau devant entretien
BL36
W385-2180 / C
FOR YOUR SAFETY:
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
CAUTION:
Do not operate the appliance
with the glass removed,
cracked or broken.
Replacement of the glass
should be done by a licensed
DWG#: W385-2180
or qualified person.
DATE: 02.24.17
POUR VOTRE
SÉCURITÉ:
Ne pas entreposer ni utiliser
d'essence ni d'autres vapeurs
ou liquides
inflammables dans le
voisinage de cet appareil ou
de tout autre appareil.
ATTENTION:
N'utiliser pas l'appareil si le
panneau frontal en verre est
enlevé, craqué ou brisé.
Remplacement du panneau
frontal en verre doit être fait
par un technicien agréé.
PAGE 2 OF 2
DWG#:
W385-2180
DATE: 02.24.17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ascent linear bl36-1Ascent linear bl46

Table des Matières