Télécharger Imprimer la page

Quick Install Guide - Enphase Energy M215 Guide D'installation Rapide

Publicité

M215 Microinverter
Attach the Microinverters to the Rail
3
a. Mark the approximate centers of each PV
module on the mounting rail. See notes in
Step Details on back.
b. Mount the microinverters with the silver side
facing up and the black side facing down.
c. If required, bond (earth) the microinverter
chassis to the mounting rail.
Dress the Cable
4
a. Use tie wraps to attach the cabling to the
mounting rail.
Keep the release holes clear
and accessible.
b. Dress any excess cabling in loops so that
it does not contact the roof.

Quick Install Guide

tie wrap
release holes
Connect the Microinverters
5
a. Remove and discard the temporary
shipping cap from the cable connector
and connect the microinverter. Listen for
two clicks as the connectors engage.
b. Cover all unused connectors with sealing
caps. Listen for two clicks as the
connectors engage. See notes in Step
Details on back.
Do not use shipping caps to
cover unused connectors. The
shipping cap does not provide an
adequate environmental seal.

Publicité

loading