After use / Empty the urn
• Switch off the appliance by setting the power
switch to position "0" and then unplug it.
• Place a container under the tap.
Maintenance tips
• Always unplug from the power socket & leave
completely cool down before cleaning the urn.
• If the boiler is subjected to heavy use, you will
need to de-scale it at regular intervals.
• Never immerse the boiler in water or other liquid
cleaning products.
Troubleshooting
Problem
Boiler does not work at all.
Boiler switches off automatically.
Boiler does not reach the selected
temperature.
When in doubt always contact your supplier!
De-scaling
The orange indicator light will be illuminated when
the urn gets too hot and needs to be cleaned. Hard
water will cause a build-up of calcium and limes-
cale on the heating element. To keep the urn in
optimum operating condition and ensure each use
will result in the best-tasting beverage, we recom-
mend de-scaling when you find build-up on the
heating element.
• Pour 100 ml fresh or condensed lemon juice on
the heating element.
• Wait 5~6 minutes to allow the lemon juice to loos-
en the build-up.
Technical specification
Item no.
Operating voltage and frequency
Rated input power
Approx. capacity
Protection class
Temperature setting range
Dimension
Remark: Technical specification is subjected to change without prior notification.
• Open the tap and drain the liquid out of the urn.
• When the boiler has been emptied, close the tap.
• Clean the boiler with a damp cloth.
• Never use abrasive or caustic cleaning products.
• Always ensure the electrical connections remain
absolutely dry.
• When you drain off dirty water, leave the tap open
and rinse the boiler with clean water.
Cause
No mains voltage.
Boiler has exceeded maximum safety
limits.
Thermostat does not work.
Heating element does not work.
• Rub lightly and gently with a brush with soft bris-
tles.
• Repeat steps 1~3, until build-up has been re-
moved.
• Use a dry cloth to wipe the lemon juice away.
• Pour some clean water into the urn and brush
the heating element lightly and gently until there
is no more lemon taste or smell.
Now you can use the urn again.
211243
6,8L
320 x 310 x (H) 425 mm
Possible solution
Check the electrical connections.
Unplug boiler and let it cool down.
Once it has cooled off, press the reset
button on the bottom.
Contact your supplier.
211250
220-240V~50Hz
950W
Class I
30 °C ~ 110°C
320 x 310 x (H) 580 mm
EN
12L
5