ePump™ and VS-FloPro™ Variable-Speed Pump Controller
2:SPEED 2 TIMECLOCK
Timeclock Operation
When the pump is stopped, the associated green LED will
illuminate, indicating a timeclock program is enabled for that
speed. If the pump has been turned on by the timeclock, the
red LED will illuminate and a timeclock icon will show in the
lower left hand corner of the display
If two (2) timed programs overlap, the program with the
faster speed will take priority and run to completion. If
the earlier-starting program is still active, it will resume
operation.
The program off times never change, i.e., they are not
'pushed-out' in time when programs overlap. Timeclock
programs may be prematurely stopped by stopping the pump
manually from the keypad. This override is active until the
program start time is reached again, at which time the timed
program will start the pump as programmed.
nOTE
When starting the pump via a timed program, the
pump will first run at the priming speed for the
priming duration, as set by the installer. If a program
overlap occurs, the pump will immediately start at the
program speed without priming first.
Manually Overriding a Timer Program
Timeclock programs may be prematurely stopped by pressing
the active speed key. This override is active until the program
start time is reached again, i.e., for 24 hours, at which time
the timed program will start the pump as programmed.
PRESS SPEED OR MENU
12:00AM
2
MENU
Timer Overriding a Manual On
If the pump is started manually at a speed that has been
programmed with a timer, the pump will be stopped by the
timeclock at the programmed off time. A clock icon appears
on the display when the timer has assumed control of the off
time.
ENABLE
PUMP IS OFF
3
4
|
Installation Manual
3.8

Keypad lock

Press and hold both arrow keys for five (5) seconds to lock
the keypad. To disable the keypad lock, repeat the procedure
while the keypad is locked.
KEYPAD LOCKED
12:00AM
2
MENU

Section 4. Service Setup Options

The service setup menu allows the installer to set various
operating parameters, view fault history, and restore factory
defaults.
Parameters that may be modified and set in the service setup
menu include:
• Priming speed and duration.

• Minimum and maximum pump speeds.

• "  " eStar speed.
• Pump Freeze Protect operation.
4.1

Entering Service Setup

nOTE
The controller must be in the
entering the user setup mode. While in setup mode
the controller will return back to the
one (1) minute since the last key press.
To enter the service setup menu, press and hold MEnU, then
press and hold the "
" and speed "4" keys. Hold all three
(3) keys down for five (5) seconds. To exit, press any speed
button.
PRESS SPEED OR MENU
12:00AM
2
4.2
Minimum and Maximum Pump
Speeds
These speeds are considered global settings across the entire
controller, and create the range of allowable speed that may
be sent to the variable-speed pump.
ENGLISH
Page 13
PUMP IS OFF
4
3
OFF
mode before
OFF
mode after
PUMP IS OFF
3
4
MENU