Ignition and Start Up
Automatic Operation:
Push and release the ON/OFF button [30] to start the
refrigerator (See Art02410).
- If the indicator light [185] glows solid green, it means
that:
- 120 volt AC power is available to the refrigerator.
- The refrigerator is operating on AC electric
power.
- If the indicator light [185] glows solid amber, it means
that:
- 120 volt AC power is not available to the refrigerator.
- The refrigerator is operating on propane gas.
- If the indicator light [185] glows solid red, it means that:
- There is a problem and the refrigerator is not cooling.
- Refer to the "Fault Code" section of this manual.
Do a test of the gas safety valve:
1. Remove the AC power cord(s) from the receptacle.
2. Push and release the ON/OFF button to start the refrigerator.
3. Open the lower intake vent.
4. Remove one wire from the solenoid of the gas safety valve at the rear of the refrigerator.
5. Within 30 seconds, the flame should extinguish. This means that the gas safety valve is operating correctly.
6. Put the wire back on the solenoid of the gas safety valve.
7. Reconnect the AC power cord(s) into the receptacle.
8. Close the lower intake vent.
Shut down:
To shut down the refrigerator, push and release the ON/OFF button.
Installation and Owner's Manual 22
Art02410
30
185