Connect the Low Ambient Heater (optional)

Connect the low ambient heater wires to the 12 volts DC supply. The black
(+) wire of the low ambient heater is 16 AWG and the brown (-) wire is 18
AWG.
1. Cut the 12V input (+) wire behind the quick connect [269]; strip both ends
(See Art02316).
2. Solder the wires with the 16AWG black wire [266].
3. Wrap the soldered wires with black electrical tape [268]; BE SURE there
are no exposed strands.
4. Cut the 12V ground wire behind the quick connect [269]; strip both ends
(See Art02317).
5. Solder the wires with the 18AWG wire [267].
6. Wrap the soldered wires with black electrical tape [268] ; BE SURE there
are no exposed strands.
7. Connect 12V supply to the input wires.
This kit supplies DC voltage to the heater any time the
NOTICE
ambient temperature is low enough. Extended storage
during cold weather will drain the vehicle batteries. To
prevent battery drain, remove the 3 amp fuse from the low
ambient heater.

Connect the Propane Gas Components

Connect the propane gas components and examine the gas supply system for leaks:
If you use compressed air for the test:
- The pressure of the compressed air at the manual shut off valve of the refrigerator must not be more than 1/2 psig (14 inches Water
Column).
- If the pressure of the compressed air is more than 1/2 psig (14 inches Water Column), remove the gas supply line from the
bulkhead fitting of the refrigerator before the test.
- If the pressure of the compressed air is equal to or less than 1/2 psig (14 inches Water Column), close the manual shut off valve of
the refrigerator before the test.
269
266
269
267
Installation and Owner's Manual 21