Residential Installation; General Installation Advice; Power Connection - Atag Descale Notice D'installation

Masquer les pouces Voir aussi pour Descale:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Residential installation

3. General advice on the installation
1. Pressure
A minimum pressure of 1.8 bars is needed to allow the valve to regenerate properly.
Please do not operate over 8 bars. If this is the case, use a pressure reducer upstream
of your installation.

2. Power connection

Be sure that power cannot be switched off accidentally at a wall switch.
If the power cable is damaged, please ask a skilled electrician to change it.
3. Plumbing
The plumbing must be in good state. In Case of doubt, please change it.
We advise the use of pre-fi lter upstream the installation.
4. Water Temperature
Feed water temperature must not exceed 35°C and complete installation must not be
allowed to freeze. (Irreversible damage).
Note : All electrical & plumbing should be done in accordance to all local codes.
6
3 METERS