4.4.4 BLADE ADJUSTMENT
The sliding doors (L, Fig. 23) for the discharging of the seeds from
the hopper, have three adjustment positions (Fig. 25):
1) Position 0: when the blade is completely lowered it closes the
seed discharge slot completely and shuts out the distributor
roller to which seeds no longer À ow.
2) Position 1: by raising the sliding doors to the ¿ rst setting,
the medium aperture position indicated in the enclosed table
forsmall seeds is obtained because the discharge slot comes
to be only partially opened.
3) Position 2: this is the position of maximum aperture that is
indicated for medium and large-sized seeds.
4.4.5 ADJUSTMENT OF THE DISTANCE BETWEEN ROWS
The width of the planting unit and the number of the furrow openers
determine the distance between rows. To change the interrow
distance, follow the diagrams shown in the Spare Parts Booklet
according to the type of furrow opener (hoe, single disc, double
disc). To increase or decrease the interrow distance for sowing,
remove or add furrow openers as follows (Fig. 26):
- unscrew the nut (N) and the screws (O).
- Once the desired number of the coulters has been obtained they
must all be set at the same distance (measured at the coulters),
and the screws tightened again.
- Make sure that only the sliding doors of the distributors that have
the telescoping tube (P, Fig. 27) are open; all the others must be
closed.
cod. G19502891
USE AND MAINTENANCE
¿ g. 25
N
O
¿ g. 26
-
1
0
ENGLISH
2
P
Fig. 27
63