Connecting the water line:
1. Turn off main water supply. Turn on nearest faucet long
enough to clear line of water.
2. Find a ¹⁄₂ in. (12.70 mm) to 1¹⁄₄ in. (3 .18 cm) vertical cold water
pipe near the ice maker.
NOTE: Horizontal pipe will work, but the following procedure
must be followed: Drill on the top side of the pipe, not the
bottom. This will help keep water away from the drill. This
also keeps normal sediment from collecting in the valve.
3. Using a grounded drill, drill a ¹⁄₄ in. (6.3 5 mm) hole in the cold
water pipe you have selected.
4. Fasten shut-off valve to cold water pipe with pipe clamp. Be
sure outlet end is solidly in the ¹⁄₄ in. (6.3 5 mm) drilled hole in
the water pipe and that washer is under the pipe clamp.
Tighten packing nut. Tighten the pipe clamp screws carefully
and evenly so washer makes a watertight seal. Do not
overtighten the pipe clamp or you may crush cold water pipe
if it is soft copper tubing. Do not use a piercing-type or ³⁄₁₆ in.
(4.76 mm) saddle-type valve which reduces water flow and
clogs more easily.
5. Now you are ready to connect the copper tubing. Use ¹⁄₄ in.
(6.3 5 mm) OD soft copper tubing for the cold water supply.
Measure from the connection at the front of the ice maker
to the cold water pipe. Add 3 feet to ensure that you have
the proper length. This is the length of ¹⁄₄ in. (6.3 5 mm) OD
soft copper tubing you need for the job. Be sure both
ends of the copper tubing are cut square.
Slip compression sleeve and compression nut on copper
tubing as shown. Insert end of tubing into outlet end
squarely as far as it will go. Screw compression nut onto
outlet end with adjustable wrench. Do not overtighten.
1. Cold Water Pipe
2. Pipe Clamp
3. Copper Tubing
4. Compression Nut
5. Compression Sleeve
6. Shut-Off Valve
7. Packing Nut
6. Place the free end of the tubing into a container or sink, and
turn on main water supply and flush out tubing until water is
clear. Turn off shut-off valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve to prevent possible
water valve malfunction.
6
7. Remove the two screws in the lower access panel and the
two screws in the base grille area of the front panel support.
Pull forward to remove the lower access panel.
8. Position the tubing so it can enter one of the two access
holes located at the right-hand rear of the cabinet as shown.
The tubing should extend beyond the cabinet front when the
cabinet is pushed back into position. Move the ice maker into
position.

REAR VIEW

1. Upper Water Line Access Hole
2. Lower Water Line Access Hole
9. Bend the copper tubing to meet the water valve inlet on the
water valve which is located in the front of the ice maker
cabinet as shown.
10. Unscrew the water valve inlet cover, and attach the copper
tubing with the compression sleeve and nut.
NOTE: To prevent rattling, be sure the copper tubing does not
touch the cabinet's side wall or other parts inside the cabinet.

FRONT VIEW

"
1. Water Pan Drain
2. Water Valve
11. Turn shut-off valve on. Check for leaks. Tighten any
connections (including connections at the valve) or nuts that
leak. The ice maker is equipped with a built-in water strainer.
If local water conditions require periodic cleaning or a well is
your source of water supply, a second water strainer should
be installed. Obtain a water strainer from your nearest
appliance dealer and install it at either tube connection.
12. Replace the lower access panel and screws.
"
15
1/4
(38.7 cm)
2
7/8
"
(7.27 cm)

Publicité

Table des Matières
loading

Table des Matières