V. Wiring
The heat pump should only be wired in by a qualified professional in accordance with the rules of the art.
The power supply should be compatible with the model selected :
Supply voltage
(Volts/phases/Hz)
Electric current
requirement (A)
Cable cross section
(mm2)
Electrical
Not adjustable
protection
(A)
Adjustable
V.1 - Control panel side:
The line feeding the heat pump must be configured and fitted with one or more devices providing for:
- proper earthing of the machine
- protection of people by means of a 30 mA residual current device (interrupter or circuit breaker) dedicated to the
pool control panel or the heat pump line (unless the house is already fitted with one)
- Protection of the machine against "overloads" and short-circuits by means of a thermo-magnetic circuit-breaker
To avoid the untimely tripping of the circuit breakers on starting up the machine, use D curve circuit breakers.
V.2 - Connections on the heat pump side:
The machine is wired through the black connection box beside the information plate.
To remove the lid of the connection box, first unscrew the 4 plastic screws.
Push the power cable up through the cable gland situated at the bottom of the connection box.
Strip the first 1 cm of each wire and connect these to the domino connector, taking care to join the phase, live,
neutral, earth correctly (N.B. : on some single phase machines, the neutral wire is grey).
Tighten the cable gland nut to immobilise the cable and ensure that the seal around the cable is leaktight
Put back the lid back on the box and screw it into position.
HC-HH 62 M
HC-HH 72 M
230/1/50
230/1/50
7 to 8.5
10.5 to 12.5
2.5
4
12
16
Set the protection to be triggered at the upper electric current requirement + 2 A
Single phase
Black wire = phase
Blue wire = neutral
Yellow/green = earth
HC-HH 92 M
HC-HH 102 M
HC-HH 102 T
230/1/50
230/1/50
400/3/50
14 to 15
14.5 to 16.5
8.0 to 10.0
4
4
2.5
20
20
12
2009/01 - Indice de révision : C - Code : 0033385
36/48
HC-HH 122 M
HC-HH 152 M
HC-HH 122 T
HC-HH 152 T
230/1/50
230/1/50
400/3/50
400/3/50
16.5 to 18.5
8.5 to 10.5
8.5 to 10.5
4
6
2.5
4
20
16
HC-HH 172 T
230/3/50
9.0 to 10.5
4
20